A very thin silicon chip is bonded to a 6-mm thick aluminum substrate by a 0.02-mm thick epoxy glue. Both surfaces of this chip-aluminum system are cooled by air at
Want to see the full answer?
Check out a sample textbook solutionChapter 2 Solutions
Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
- 2.38 The addition of aluminum fins has been suggested to increase the rate of heat dissipation from one side of an electronic device 1 m wide and 1 m tall. The fins are to be rectangular in cross section, 2.5 cm long and 0.25 cm thick, as shown in the figure. There are to be 100 fins per meter. The convection heat transfer coefficient, both for the wall and the fins, is estimated to be K. With this information determine the percent increase in the rate of heat transfer of the finned wall compared to the bare wall.arrow_forwardAn electronic device that internally generates 600 mW of heat has a maximum permissible operating temperature of 70C. It is to be cooled in 25C air by attaching aluminum fins with a total surface area of 12cm2. The convection heat transfer coefficient between the fins and the air is 20W/m2K. Estimate the operating temperature when the fins are attached in such a way that (a) there is a contact resistance of approximately 50 K/W between the surface of the device and the fin array and (b) there is no contact resistance (in this case, the construction of the device is more expensive). Comment on the design options.arrow_forwardEstimate the rate of heat loss per unit length from a 5-cm ID, 6-cm OD steel pipe covered with high-temperature insulation having a thermal conductivity of 0.11 W/(m K) and a thickness of 1.2 cm. Steam flows in the pipe. It has a quality of 99% and is at 150C. The unit thermal resistance at the inner wall is 0.0026(m2K)/W the heat transfer coefficient at the outer surface is 17W/(m2K) and the ambient temperature is 16C.arrow_forward
- 3.10 A spherical shell satellite (3-m-OD, 1.25-cm-thick stainless steel walls) re-enters the atmosphere from outer space. If its original temperature is 38°C, the effective average temperature of the atmosphere is 1093°C, and the effective heat transfer coefficient is , estimate the temperature of the shell after reentry, assuming the time of reentry is 10 min and the interior of the shell is evacuated.arrow_forward1.10 A heat flux meter at the outer (cold) wall of a concrete building indicates that the heat loss through a wall of 10-cm thickness is . If a thermocouple at the inner surface of the wall indicates a temperature of 22°C while another at the outer surface shows 6°C, calculate the thermal conductivity of the concrete and compare your result with the value in Appendix 2, Table 11.arrow_forward2.9 In a large chemical factory, hot gases at 2273 K are cooled by a liquid at 373 K with gas-side and liquid-side convection heat transfer coefficients of 50 and , respectively. The wall that separates the gas and liquid streams is composed of a 2-cm thick oxide layer on the gas side and a 4-cm thick slab of stainless steel on the liquid side. There is a contact resistance between the oxide layer and the steel of . Determine the rate of heat loss from hot gases through the composite wall to the liquid.arrow_forward
- Determine the rate of heat transfer per meter length to a light oil flowing through a 2.5-cm-ID, 60-cm-long copper tube at a velocity of 0.03 m/s. The oil enters the tube at 16C, and the tube is heated by steam condensing on its outer surface at atmospheric pressure with a heat transfer coefficient of 11.3 kW/m K. The properties of the oil at various temperatures are listed in the following table: Temperature, T(C) 15 30 40 65 100 (kg/m3) 912 912 896 880 864 c(kJ/kgK) 1.80 1.84 1.925 2.0 2.135 k(W/mK) 0.133 0.133 0.131 0.129 0.128 (kg/ms) 0.089 0.0414 0.023 0.00786 0.0033 Pr 1204 573 338 122 55arrow_forwardThe interior wall of a large, commercial walk-in type meat freezer is covered under normal operating conditions with a 2-cm thick layer of ice. One day, a power outage cuts electricity to the refrigeration system of the freezer. Estimate the time required to melt this layer of ice if it has a mass density of 700kg/m3 and a latent heat of fusion of 334 kJ/kg. Consider the air temperature inside the freezer to be 20C with a heat transfer coefficient of 2W/m2K for convection from the freezer surface to air, and clearly state the assumptions made in your calculations.arrow_forwardA cooling system is to be designed for a food storage warehouse for keeping perishable foods cool prior to transportation to grocery stores. The warehouse has an effective surface area of 1860 m2 exposed to an ambient air temperature of 32C. The warehouse wall insulation (k=0.17W/(mK)) is 7.5 cm thick. Determine the rate at which heat must be removed (W) from the warehouse to maintain the food at 4C.arrow_forward
- 2.30 An electrical heater capable of generating 10,000 W is to be designed. The heating element is to be a stainless steel wire having an electrical resistivity of ohm-centimeter. The operating temperature of the stainless steel is to be no more than 1260°C. The heat transfer coefficient at the outer surface is expected to be no less than in a medium whose maximum temperature is 93°C. A transformer capable of delivering current at 9 and 12 V is available. Determine a suitable size for the wire, the current required, and discuss what effect a reduction in the heat transfer coefficient would have. (Hint: Demonstrate first that the temperature drop between the center and the surface of the wire is independent of the wire diameter, and determine its value.)arrow_forward2.2 A small dam, which is idealized by a large slab 1.2 m thick, is to be completely poured in a short Period of time. The hydration of the concrete results in the equivalent of a distributed source of constant strength of 100 W/m3. If both dam surfaces are at 16°C, determine the maximum temperature to which the concrete will be subjected, assuming steady-state conditions. The thermal conductivity of the wet concrete can be taken as 0.84 W/m K.arrow_forward1.67 In beauty salons and in homes, a ubiquitous device is the hairdryer. The front end of a typical hairdryer is idealized as a thin-walled cylindrical duct with a 6-cm diameter with a fan at the inlet that blows air over an electric heating coil as schematically shown in the figure. The design of this appliance requires two power settings, with which the air blown over the electric heating coil is heated from the ambient temperature of to an outlet temperature of and with exit air velocities of 1.0 m/s and 1.5 m/s. Estimate the electric power required for the heating coil to meet these conditions, assuming that heat loss from the outside of the dryer duct is neglected.arrow_forward