To determine
Find the heat-transfer rate through the door.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Calculate the total heat loss from a house measures L×w in plan. The height of walls is H. The house has front and bake external doors, the area of each door is A1m2, and four glass windows with total area of A2m2 the U-value of building elements as the following:
Assume the specific heat capacity of air is CpJ/m3I and the air is changed once per hour. The design internal temperature is T1°C and external temperature is T2°C. Assume the value of N as 0.6. Where
Qf =Σ (U×A×ΔT) watt
Qv= (Cv×N×V×ΔT)÷3600 watt
100°? air flows through a round aluminum tube of ID 60mm and OD 80mm at 4 ?? .The tube is covered in 5mm thick fiberglass insulation. The tube is surrounded by RT air flowing at 5?? over the outside of the insulation. What is the heat rate through the wall of the tube? Assume that the air temperature is constant throughout the tube.
Note: RT is 25 celsius
H.WII Cooling Load Estimation
An air conditioned room in the Basra city that
measures 3 m wide, 3.5 m high and 6 m deep. The
window size 1.5 m*1.5 m, mounted on the wall with no
external shading and the door size 2m*1m.
Calculate the sensible, latent and total heat gains on
the room. What is the required cooling capacity?
Assume all specification parameters that must be
taken into account when calculating cooling load.
6 m
2 *1 m
3 m
1.5 * 1.5 m
NW
NE
LNL
E
ESE
SSW
SSF
SW
SE
Chapter 11 Solutions
ENGINEERING FUNDAMENTALS
Ch. 11.2 - Prob. 1BYGCh. 11.2 - Prob. 2BYGCh. 11.2 - Prob. 3BYGCh. 11.2 - Prob. 4BYGCh. 11.2 - Prob. 5BYGCh. 11.2 - Prob. BYGVCh. 11.4 - Prob. 1BYGCh. 11.4 - Prob. 2BYGCh. 11.4 - Prob. 3BYGCh. 11.4 - Prob. 4BYG
Ch. 11.4 - Prob. BYGVCh. 11.6 - Prob. 1BYGCh. 11.6 - Prob. 2BYGCh. 11.6 - Prob. 3BYGCh. 11.6 - Prob. 4BYGCh. 11.6 - Prob. BYGVCh. 11 - Prob. 1PCh. 11 - Prob. 2PCh. 11 - Alcohol thermometers can measure temperatures in...Ch. 11 - Prob. 4PCh. 11 - Prob. 5PCh. 11 - Prob. 6PCh. 11 - Prob. 7PCh. 11 - Prob. 8PCh. 11 - Calculate the R-value for the following materials:...Ch. 11 - Calculate the thermal resistance due to convection...Ch. 11 - Prob. 11PCh. 11 - Prob. 12PCh. 11 - Prob. 13PCh. 11 - Estimate the change in the length of a power...Ch. 11 - Calculate the change in 5 m long copper wire when...Ch. 11 - Prob. 16PCh. 11 - Prob. 17PCh. 11 - Prob. 19PCh. 11 - Prob. 20PCh. 11 - Prob. 23PCh. 11 - Prob. 24PCh. 11 - Prob. 26PCh. 11 - Prob. 27PCh. 11 - Prob. 28PCh. 11 - Prob. 29PCh. 11 - Prob. 30PCh. 11 - Prob. 31PCh. 11 - Prob. 32PCh. 11 - Prob. 33PCh. 11 - Prob. 34PCh. 11 - Prob. 35PCh. 11 - For Problems 11.11, 11.12, and 11.13, calculate...Ch. 11 - Prob. 37PCh. 11 - Prob. 38PCh. 11 - Prob. 39PCh. 11 - Prob. 40PCh. 11 - Prob. 41PCh. 11 - Prob. 42PCh. 11 - Prob. 43PCh. 11 - Prob. 44PCh. 11 - Prob. 45PCh. 11 - Prob. 46PCh. 11 - Prob. 47PCh. 11 - Prob. 48PCh. 11 - Prob. 49PCh. 11 - Prob. 51PCh. 11 - Prob. 52PCh. 11 - Prob. 53PCh. 11 - Prob. 54PCh. 11 - Prob. 55P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- Calculate the thermal resistance due to convection for the following situations: a. warm water with h = 200 W/m2 K b. warm air with h = 10 W/m2 K c. warm moving air (windy situation) h = 30 W/m2 Karrow_forwardPls. Answer thank you! A room's sensible space load is from occupants and infiltration, but excluding intentional ventilation, is 3.2 kw. A total of 600 L/s of outside air is required. What is most nearly the room sensible heat ratio?arrow_forwardA room 3.6m x 5m x 8m fully replaces inside air after 3 hours. If the temperature from the outside is 80 F and temperature inside is 60F. Determine the ventilation heat load in Watts. subject Engineering utilities 2arrow_forward
- Convert the temperature of scalding water, 54 °C, into degrees Fahrenheit and kelvin.arrow_forwardA forced air system takes return air at 62 degrees Fahrenheit (°F). It heats theair 59°F. What is the temperature of the heated air blown out to the room?arrow_forwardCalculate the density of air at standard conditions (T - 25 °C and P a 1 atm).arrow_forward
- A line was measured using a 50m tape and was recorded as 746.22m. when the average temperature during measurement was 16°C. If the tape is of standard length at 20°C and a coefficient of thermal expansion of 0.0000116m/°C. Compute the correct length of the measured line.arrow_forwardCalculate the heat loss from a double-pane glass window consisting of two pieces of glass, each having a thickness of 10 mm with a thermal conductivity of k = 1.3 W/m.K . The two glass panes are separated by an air gap of 7 mm. Assume thermal conductivity of air to be k = 0.022 W/m.K .arrow_forward17-A refrigerator is to remove heat from the cooled space at a rate of 300 kJ/min to maintain its temperature at -8°C. Wam in.min REFRIG. 300 25°C -8°C kJ/minarrow_forward
- Compute the pressure heat a m, in feet of fluid A, indicated by open manometer in figure below when; (a) Fluid is oil (sp gr 0.895), the gage liquid is carbon tetrachloride (sp gr 1.95), y = 30.75 inch, z = 30.95 in(b) Fluid A is molasses (sp gr) 1.50), the gage liquid is water, y = 3.95ft, z = 1.75ft Note: Clear handwritten solutionarrow_forwardConvert: Convert a (15.5 °C+ 17) temperature into °F temperature.arrow_forwardExercise 2: According to an appliance manufacturer, the 4-in.-diameter vent on a clothes dryer is not to contain more than 20 ft of pipe and four 90° elbows. Under these conditions determine the air volumetric flow rate if the gage pressure within the dryer is 0.20 inches of water. Assume both the specific weight and the kinematic viscosity of the heated air to be constant and equal to y=0.0709 bf/ft?, and v=µp=1.79x10 -4 ft2/s, respectively, and that the roughness of the vent pipe surface is equivalent to that of galvanized iron. C20 0.2 in. V-0 (2) Figure K: Schematic for Exercise 2, Moran&Shapiro, 2002 O KFVD) = 3.87 O K fVD)= 3.67) O K/ (FVD) = 3.79 O K/ (FVD) = 3.74arrow_forward