*It required to design a ducting system to condition the building shown in figure (1). The uantity of outdoor is (20%) of supply air. Using information in table, find 1- The sensible and latent load for cooling coil. 2- The quantity and condition of supply air to each place. 3- By using equal pressure drop method, design the rectangular ducting system with maximum height side (600mm). 4- Illustrate the all process on psychometric chart. Outdoor 45 °C db & 30% RH Out let type Celling

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
* It required to design a ducting system to condition the building shown in figure (1). The
uantity of outdoor is (20%) of supply air. Using information in table, find
1- The sensible and latent load for cooling coil.
2- The quantity and condition of supply air to each place.
3- By using equal pressure drop method, design the rectangular ducting system with
maximum height side (600mm).
4- Illustrate the all process on psychometric chart.
Outdoor
45 °C db & 30% RH
Out let type
Celling
conditioning
indoor conditioning 24 °C db & 50% RH
diffuser
Number of diffuser
2 for each
place
15 kpa
10 kpa
15 kpa
By pass factor
Apparatus dew point 9°C
Ap losses diffuser
Ap losses filter
Ap losses coil
0.15
R/w
1.5
6m
6m
6m
Room (1)
Room (2)
Room (3)
4m
RSH=8KW
RSH=6KW
RSH=8KW
RLH=2KW
RLH=1KW
RLH=2KW
2m
AHU
Mechanical
Room (4)
RSH=20KW
4m
Room
RLH=3KW
4m
14m
Transcribed Image Text:* It required to design a ducting system to condition the building shown in figure (1). The uantity of outdoor is (20%) of supply air. Using information in table, find 1- The sensible and latent load for cooling coil. 2- The quantity and condition of supply air to each place. 3- By using equal pressure drop method, design the rectangular ducting system with maximum height side (600mm). 4- Illustrate the all process on psychometric chart. Outdoor 45 °C db & 30% RH Out let type Celling conditioning indoor conditioning 24 °C db & 50% RH diffuser Number of diffuser 2 for each place 15 kpa 10 kpa 15 kpa By pass factor Apparatus dew point 9°C Ap losses diffuser Ap losses filter Ap losses coil 0.15 R/w 1.5 6m 6m 6m Room (1) Room (2) Room (3) 4m RSH=8KW RSH=6KW RSH=8KW RLH=2KW RLH=1KW RLH=2KW 2m AHU Mechanical Room (4) RSH=20KW 4m Room RLH=3KW 4m 14m
Expert Solution
steps

Step by step

Solved in 6 steps with 8 images

Blurred answer
Knowledge Booster
Automation of Manufacturing Processes
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY