two synchronous generators are connected in parallel, feeding a load together. the frequency of the first generator in the no-load State is 52 Hz and the slope of the characteristic is 1 MW/Hz. the total power of the load fed by these two generators is 2.5 MW and the power coefficient is 0.6 inductive. by drawing the characteristic curve of the system; a) what is the frequency of the system when the load in question is fed, and how do the two generators share the load between themselves b) if a load of 0.5 MW is added to the system, find the operating frequency of the new system and the powers given by each generator c) if a second load of 0.5 MW is connected to the system, the idle operating frequency of the second generator is increased by 0.5 Hz, what happens to the operating frequency of the system and the power values given by the generators

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.16P: A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and...
icon
Related questions
icon
Concept explainers
Question

two synchronous generators are connected in parallel, feeding a load together. the frequency of the first generator in the no-load State is 52 Hz and the slope of the characteristic is 1 MW/Hz. the total power of the load fed by these two generators is 2.5 MW and the power coefficient is 0.6 inductive. by drawing the characteristic curve of the system;
a) what is the frequency of the system when the load in question is fed, and how do the two generators share the load between themselves
b) if a load of 0.5 MW is added to the system, find the operating frequency of the new system and the powers given by each generator
c) if a second load of 0.5 MW is connected to the system, the idle operating frequency of the second generator is increased by 0.5 Hz, what happens to the operating frequency of the system and the power values given by the generators

Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning