The tolerance of a Class A 25 mL transfer pipet is +0.03 mL. A student uses an uncalibrated Class A transfer pipet to deliver a total of 125 mL of solution. What is the uncertainty in the delivered 125 mL? 0.15 mL 土 Next, the student calibrates the pipet. The calibrated pipet delivers a mean volume of 24.995 mL with an uncertainty of +0.006 mL. The student then uses the calibrated 25 mL pipet to deliver a total of 124.975 mL of solution. What is the uncertainty in the delivered 124.975 mL? 0.375 mL Incorrect How does the uncertainty in the delivered volume using the calibrated pipet compare to the uncertainty in the delivered volume using the uncalibrated pipet? O The uncertainty in the delivered volume is the same for the calibrated and uncalibrated pipet. O The uncertainty in the delivered volume using the calibrated pipet is greater than the uncertainty in the delivered volume using the uncalibrated pipet. O The unceainty in the delivered volume using the calibrated pipet is less than the uncertainty in the delivered volume using the uncalibrated pipet. étv AA A O hulu MacBook Pro

Principles of Modern Chemistry
8th Edition
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
ChapterA: Scientific Notation And Experimental Error
Section: Chapter Questions
Problem 8P
icon
Related questions
Question
The tolerance of a Class A 25 mL transfer pipet is +0.03 mL. A student uses an uncalibrated Class A transfer pipet to deliver a
total of 125 mL of solution. What is the uncertainty in the delivered 125 mL?
mL
0.15
Next, the student calibrates the pipet. The calibrated pipet delivers a mean volume of 24.995 mL with an uncertainty of
+0.006 mL. The student then uses the calibrated 25 mL pipet to deliver a total of 124.975 mL of solution. What is the
uncertainty in the delivered 124.975 mL?
0.375
mL
Incorrect
How does the uncertainty in the delivered volume using the calibrated pipet compare to the uncertainty in the delivered
volume using the uncalibrated pipet?
O The uncertainty in the delivered volume is the same for the calibrated and uncalibrated pipet.
O The uncertainty in the delivered volume using the calibrated pipet is greater than the uncertainty in the delivered
volume using the uncalibrated pipet.
O The uncerainty in the delivered volume using the calibrated pipet is less than the uncertainty in the delivered volume
using the uncalibrated pipet.
山T四ae
étv AA A O
hulu
MacBook Pro
G Search or type URL
Transcribed Image Text:The tolerance of a Class A 25 mL transfer pipet is +0.03 mL. A student uses an uncalibrated Class A transfer pipet to deliver a total of 125 mL of solution. What is the uncertainty in the delivered 125 mL? mL 0.15 Next, the student calibrates the pipet. The calibrated pipet delivers a mean volume of 24.995 mL with an uncertainty of +0.006 mL. The student then uses the calibrated 25 mL pipet to deliver a total of 124.975 mL of solution. What is the uncertainty in the delivered 124.975 mL? 0.375 mL Incorrect How does the uncertainty in the delivered volume using the calibrated pipet compare to the uncertainty in the delivered volume using the uncalibrated pipet? O The uncertainty in the delivered volume is the same for the calibrated and uncalibrated pipet. O The uncertainty in the delivered volume using the calibrated pipet is greater than the uncertainty in the delivered volume using the uncalibrated pipet. O The uncerainty in the delivered volume using the calibrated pipet is less than the uncertainty in the delivered volume using the uncalibrated pipet. 山T四ae étv AA A O hulu MacBook Pro G Search or type URL
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Modern Chemistry
Principles of Modern Chemistry
Chemistry
ISBN:
9781305079113
Author:
David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:
Cengage Learning
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning