Pick the right combination of True Statements. 1. As the by-pass factor (BPF) of the cooling coil increases, temperature difference between air at the outlet of the coil and coil ADP decreases. 2. As the by-pass factor (BPF) of the cooling coil increases, temperature difference between air at the outlet of the coil and coil ADP increases. 3. During cooling and humidification process, the enthalpy of air may increase, decrease or remain constant depending upon the temperature of the wet surface. 4. During sensible cooling of air, dry bulb temperature decreases but wet bulb temperature remains constant 5. The sensible heat factor for a sensible heating process is 1.0

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter3: Refrigeration And Refrigerants
Section: Chapter Questions
Problem 31RQ: Define a near-azeotropic refrigerant blend, and give twoexamples.
icon
Related questions
icon
Concept explainers
Question
Pick the right combination of True Statements.
1. As the by-pass factor (BPF) of the cooling coil increases, temperature difference
between air at the outlet of the coil and coil ADP decreases.
2. As the by-pass factor (BPF) of the cooling coil increases, temperature difference
between air at the outlet of the coil and coil ADP increases.
3. During cooling and humidification process, the enthalpy of air may increase, decrease
or remain constant depending upon the temperature of the wet surface.
4. During sensible cooling of air, dry bulb temperature decreases but wet bulb
temperature remains constant
5. The sensible heat factor for a sensible heating process is 1.0
Transcribed Image Text:Pick the right combination of True Statements. 1. As the by-pass factor (BPF) of the cooling coil increases, temperature difference between air at the outlet of the coil and coil ADP decreases. 2. As the by-pass factor (BPF) of the cooling coil increases, temperature difference between air at the outlet of the coil and coil ADP increases. 3. During cooling and humidification process, the enthalpy of air may increase, decrease or remain constant depending upon the temperature of the wet surface. 4. During sensible cooling of air, dry bulb temperature decreases but wet bulb temperature remains constant 5. The sensible heat factor for a sensible heating process is 1.0
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Chemical and Phase Equilibrium
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning