esc 1 tab Q Cock A F1 2 IIISI Question 3. A 12-kVA, 480/120V, step-down ideal transformer is operating at its full load with a 70.7% pf lagging. Determine (a) the secondary winding current magnitude and angle, (b) the load impedance seen from the primary (480V) side. Question 4. The following data were taken for a 46-kVA, 230/2300V, 60-Hz transformer: Voltage (V) Current (A) Power (W) Short-circuit test 160 20 1150 Determine (a) the equivalent winding resistance ReH of the transformer at the high-voltage side, and (b) the copper loss at 50% load. ne 47 G 18 e
Q: Calculate the current and voltage across each resistor in the network as shown in Figure 4.26. = = 4…
A: Given:with we need to find current through and voltage across each resistor.
Q: Please answer in typing format
A: Given:an op-amp circuit,with we need to find:a) the output voltage. b) explain what effect the…
Q: Required information A 110-V rms, 60-Hz source is applied to a load impedance Z. The apparent power…
A: RMS (Root Mean Square) current is a measure of the effective or equivalent continuous current that…
Q: Calculate the time required for the energy stored in the capacitor to reach 10% of its maximum…
A: The capacitor to reach 105 of its maximum value, , To calculate the time required for the energy…
Q: 4.) An unbalanced four-wire Y-Y circuit is shown in Figure 3. (a) Find the line currents ia, ib, ic,…
A: In this questionWe need to determine line currents and power absorbed by each load. We knowComplex…
Q: For the circuit shown, find V1 & V2. 10Ω W 0000 10/0° + +j200 12 W V₂ 15 Ω 13 -j50
A: In this question, we need to determine the voltages V1 and V2 as shown in the circuit. We solve this…
Q: Needs Complete solution
A: The objective of the question is to determine whether the voltage level at the customer's end is…
Q: 2.3. An inductive load consisting of R and X in series feeding from a 2400- supply absorbs 288 kW at…
A:
Q: Part B: Effect of K on closed-loop Control Response Plant C(s) Controller R(s) 1 K S² +55 +1 Figure…
A: Given:a control system,we need to do:i) find the closed loop transfer fucntion. ii) using MATLAB, we…
Q: 2.6
A: Detailed solution is provided below.Explanation:Step 1: Step 2: Step 3: Step 4:
Q: VIÐ) R₁ www R3 R2 C₁ Ry HH L₁ чи R5 ww 42 ง m чи www L C3
A:
Q: The question is accompanied with the uploaded image:
A: a) Determine which one of the two BJTs is ON which one is OFFGiven an input voltage of -5V:For Q1 to…
Q: H.W: Two point charges of 0.7mc and 4-9, Mc. are situated in free space at (2,3,6) and C0,0,0).…
A: The charge is and Calculate the force acting on the 0.7mC charge.The force is given by this formula
Q: 4. For the ripple counter in Figure 9-66, show the complete timing diagram for sixteen clock pulses.…
A: The circuit diagram,
Q: This is a practice question from the Signal and Systems course of my Electrical Engineering Program.…
A: These Fourier transform can be solved by two technique.1. Using Fourier transform properties which I…
Q: Four capacitors are connected as shown in Figure P16.33 (C = 17.0 µF). C 3.00 µF HH 20.0 F HH 6.00…
A: The given circuit is⇒C=17.0 μF.We need to determine a. The equivalent capacitance between points a…
Q: This is a practice question from the Signal and Systems course of my Electrical Engineering Program.…
A: a) -wb) 7c) 4πd) 5.5e) 38/3f) AttachedExplanation:Since phase of real signal is zero, X(jw) has 0…
Q: Needs Complete typed solution with 100 % accuracy.
A: The objective of the question is to find the output voltage (vo) for the given circuit elements. The…
Q: 3. Replace the circuit 'seen' by the 4 k to find the voltage Vo across the 4 k equivalent instead.…
A:
Q: Given A=ax+ay, B=ax+2az, and C=2ay+az, find (AB)×C and compare it with AX(BXC). Problem Solving 15
A: Since you have posted the multiple questions so we are supposed to answer the 1st answer.In the…
Q: Q1\Calculate the total DC resistance of a 100 meter roll of 2.5mm² copper wire if the resistivity of…
A: According to the question, we need to calculate the total DC resistance of a 100 m roll of 25 mm2…
Q: Please use MESH CURRENT METHOD in finding the Norton Equivalent circuit as seen by V3
A: The Nortons equivalent seen by V3 has been calculated using Mesh current method. If any doubt…
Q: 1. For the circuit below: a) Determine the initial conditions i, (0+)and v. (0*). You must show the…
A: In d.c. analysis, under steady state condition, the inductor will behave as short circuit and…
Q: Required information Assume an operating frequency of 170.0 rad/s. Find a series equivalent of the…
A:
Q: For the circuit shown in the figure, determine the impedance Zin seen by the source when R1 = 4.6 Ω.…
A: The circuit diagram,
Q: EEE 4021 Assignment 2: 2. Three point charges are placed at the corners of an equilateral triangle,…
A:
Q: Determine the transfer function of the systems whose input-output behavior is shown below (It is not…
A: The input-output plots of two systems are given. It is asked to determine the transfer function of…
Q: (a) Design the block diagram of an Armstrong indirect FM modulator to generate an FM signal with a…
A: we need to design Armstrong Indirect FM modulator to generate FM signal as per the given…
Q: Q3\ Draw the symbols of the following electronic devices. 1- coil, 2- Zener diode, 3- npn…
A: Draw the symbols of the following electronic devices1- coil, 2- Zener diode,3- npn transistor, 4-…
Q: 1. Given the following circuit: V1 -10V R1 w 3.Q R2 w 5Ω Determine: 1. R1, R2, R3, IR4, IRS 2. VR1,…
A: In this question, we need to determine the currents in each resistances , voltage across the each…
Q: 1.3
A: The voltage across the inductor is VL(t)= L×di(t)/dt. Explanation:
Q: In the circuit, find i(t) and iR(t) for +>0. t=0 A ЧА (Т 20H elle 202 202 ma ↓iR + 80mF ± 304 (-t) V
A:
Q: A series RLC circuit has a capacitor with a capacitance of 33.0 uF, an inductor with an inductance…
A:
Q: REPRESENTATION Decimal Sign-and-magnitude 1's complement 1110 1111 01110 Convert the following…
A: According to questions we need to find 2's representation of decimal no. -14.25.
Q: I only need help with the second question, but it relies on information from the first. Thank you!
A: Please refer below pages.If you have any doubts please feel free to ask.Explanation:Step 1: Step 2:…
Q: Question 4-) Using Thevenin's theorem, find vo in the circuit shown below. 3i io 4 Ω 2 H www m 12…
A: Kirchhoff's Current Law (KCL) is a fundamental principle in electrical engineering that states that…
Q: EXAMPLE 1: Layout For this problem you need to draw the layout of an inverter, NAND2 and NOR2 in…
A: The objective of this question is to design the layout of an inverter, NAND2, and NOR2 in Cadence,…
Q: Q1) You are asked to use the Arduino UNO development board to control different brightness of the…
A: Details solution is given below Explanation:Step 1:Here the LED can be connected to any PWM ins of…
Q: 1. 4.1 Consider the combinational circuit shown in Fig. P4.1. (HDL- see Problem 4.49) A B C D T3 F₁…
A: The required Boolean expression can be obtained by using the logic diagram and the same can be…
Q: Lens 18mm FL PASCO Acientific Component Adjustable mirror Movable mirror PRECISION INTERFEROMETER…
A: Answer of this is given below in explanation.Explanation:
Q: 7-2) Similar to Lathi & Ding, Prob. P.4.8-3 A shortwave radio receiver designed to operate in the 49…
A: Given:in short wave radio, the IF is 455 kHz, a receivers is designed to receive shortwave…
Q: 11- Consider an analog signal given by s(t) = 2 cos(2π 100t) cos (2π10t) is sampled at the rate of…
A: According to the question, the analog signal is given byThe signal is sampled at the rate of 250…
Q: w = 5 3 10° A 20mF 2H 40mF лее 1H www که 100 (05-90° A
A:
Q: Using Mesh analysis find Vo in the circuit. 60 ww 492 60 V 20 Ω www 20 Ω +1 5%
A: In this question, we need to determine the voltage Vo using the mesh analysis.
Q: For circuit above, solve for the current through resistor R3 (202) and the power dissipated by R3…
A:
Q: Please use MESH CURRENT Method in finding Va, I4, and Is. Give clear and proper step by step…
A: Va = 2 VI4 = -1 mAIs = 2 mAExplanation:
Q: Calculate all the values from the formulas given below: Area = 402.88mm^2, Capacitance = 1.11592 x…
A: For a piezoelectric capacitive transducer, the following data is given:Area A=402.88 mm2,Capacitance…
Q: 3. The following figure shows the circuit for a full-wave bridge rectifier. Assume the diodes are…
A: Since you have posted the questions with multiple subparts. So we are supposed to answer 1st 3…
Q: Use Nodal analysis to find (a) current flowing through all the branches in the following circuit-3…
A: Given a circuit and asked to find the branch currents and power dissipated in R10 resistor.
Q: ₁(t) +5y1(t) - - 10[y2(t) − y₁(t)] = u₁(t) - 22(t) + 2(t) + 10[y2(t) − y₁(t)] = u₂(t)
A: Given the flowing diffrential equationdefine the state variables and derive the coefficient matrix…
Question 3
Step by step
Solved in 1 steps
- Consider Figure 3.4. For an ideal phase-shifting transformer, the imda nce is unchanged when it is referred from one side to the other. (a) True (b) FalseA single-phase two-winding transformer rated 90MVA,80/120kV is to be connected as an autotransformer rated 80/200kV. Assume that the transformer is ideal. (a) Draw a schematic diagram of the ideal transformer connected as an autotransformer. showing the voltages, currents, and dot notation for polarity. (b) Determine the permissible kVA rating of the autotransformer if the winding currents and voltages are not to exceed the rated values as a two-winding transformer. How much of the kA rating is transferred by magnetic induction?A single-phase l0-kVA,2300/230-volt,60-Hz two-winding distribution transformer is connected as an autotransformer to step up the voltage from 2300 to 2530 volts (a) Draw a schematic diagram of this arrangement, showing all voltages and currents when delivering full load at rated voltage. (b) Find the permissible kVA rating of the autotransformer if the winding currents and voltages are not to exceed the rated values as a two-winding transformer. How much of this kVA rating is transformed by magnetic induction? (C) The following data are obtained from tests carried out on the transformer when it is connected as a two-winding transformer: Open-circuit test with the low-voltage terminals excited: Applied voltage =230V, input current =0.45A, input power =70W. Short-circuit test with the high-voltage terminals excited: Applied voltage =120, input current =4.5A, input power =240W. Based on the data, compute the efficiency of the autotransformer corresponding to full load, rated voltage, and 0.8 power factor lagging. Comment on why the efficiency is higher as an autotransformer than as a two-winding transformer.
- Consider a bank of this single-phase two-winding transformers whose high-voltage terminals are connected to a three-phase, 13.8-kV feeder. The low-voltage terminals are connected to a three-phase substation load rated 2.0 MVA and 2.5 kV. Determine the required voltage, current, and MVA ratings of both windings of each transformer, when the high-voltage/low- voltage windings are connected (a) Y-, (b) -Y, (c) Y-Y, and (d) -.Three single-phase, two-winding transformers, each rated 450MVA,20kV/288.7kV, with leakage reactance Xeq=0.10perunit, are connected to form a three-phase bank. The high-voltage windings are connected in Y with a solidly grounded neutral. Draw the per-unit equivalent circuit if the low-voltage windings are connected (a) in with American standard phase shift or (b) in Y with an open neutral. Use the transformer ratings as base quantities. Winding resistances and exciting current are neglected.A three-phase transformer is rated 1000MVA,220Y/22kV. The Y-equivalent short-circuit impedance, considered equal to the leakage reactance, measured on the low-voltage side is 0.1. Compute the per-unit reactance of the transformer. In a system in which the base on the high-voltage side of the transformer is 100MVA,230kV what value of the per-unit reactance should be used to represent this transformer?
- Three single-phase two-winding transformers, each rated 3kVA,220/110volts,60Hz, with a 0.10 per-unit leakage reactance, are connected as a three-phase extended autotransformer bank, as shown in Figure 3.36(c). The low-voltage winding has a 110 volt rating. (a) Draw the positive-sequence phasor diagram and show that the high-voltage winding has a 479.5 volt rating. (b) A three-phase load connected to the low-voltage terminals absorbs 6 kW at 110 volts and at 0.8 power factor lagging. Draw the per-unit impedance diagram and calculate the voltage and current at the high-voltage terminals. Assume positive-sequence operation.A single-phase 50-kVA,2400/240-volt,60-Hz distribution transformer is used as a step-down transformer at the load end of a 2400-volt feeder whose series impedance is (1.0+j2.0) ohm. The equivalent series impedance of the transformer is (1.0+j2.5) ohms referred to the high-voltage (primary) side. The transformer is delivering rated load at a 0.8 power factor lagging and at a rated secondary voltage. Neglecting the transformer exciting current, determine (a) the voltage at the transformer primary terminals, (b) the voltage at the sending end of the feeder, and (c) the real and reactive power delivered to the sending end of the feeder.In developing per-unit circuits of systems such as the one shown in Figure 3.10. when moving across a transformer, the voltage base is changed in proportion to the transformer voltage ratings. (a) True (b) False
- The leakage reactance of a three-phase, 300-MVA,230Y/23-kV transformer is 0.06 per unit based on its own ratings. The Y winding has a solidly grounded neutral. Draw the per-unit equivalent circuit. Neglect the exciting admittance and assume the American Standard phase shift.Consider the single-line diagram of the power system shown in Figure 3.38. Equipment ratings are Generator 1: 1000MVA,18kV,X=0.2perunit Generator 2: 1000MVA,18kV,X=0.2p.u. Synchronous motor 3: 1500MVA,20kV,X=0.2p.u. Three-phase -Y transformers T1,T2,T3,T4,: 1000MVA,500kV,Y/20kV,X=0.1p.u. Three-phase YY transformer T5: 1500MVA,500kV,Y/20kVY,X=0.1p.u. Neglecting resistance, transformer phase shift, and magnetizing reactance, draw the equivalent reactance diagram. Use a base of 100 MA and 500 kV for the 50-ohm line. Determine the per-unit reactances.Why is it important to reduce the moisture within a transformer to acceptable levels during transformer installation?