Design a ladder program to run the material mixing system according to the following information: 1- When the start push button 10.0 is pressed, the pump (PUMP1 Q0.0) works for five seconds and then stops. 2- After that, the pump (PUMP2 Q0.1) runs for three seconds and then stops. 3- After that the pump (Mixer Motor Q0.2) works for 60 sec and then stops. 4- After that, the control valve (drian valve Q0.3) is opened, the pump (PUMP3 Q0.4) works for ten seconds. 5- The stop push button 10.1 is used to stop the system. Chemical 1) Pump 1 (00.0) Start (10.0) Stop (10.1) Process Control Pump 2 (99.1) Mixer Motor (90.2) Drain Valve (Q0.3) Pump 3 (90.4) Chemical2

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Design a ladder program to run the material mixing system according to the following
information:
1- When the start push button 10.0 is pressed, the pump (PUMP1 Q0.0) works for five
seconds and then stops.
2- After that, the pump (PUMP2 Q0.1) runs for three seconds and then stops.
3- After that the pump (Mixer Motor Q0.2) works for 60 sec and then stops.
4- After that, the control valve (drian valve Q0.3) is opened, the pump (PUMP3 Q0.4) works
for ten seconds.
5- The stop push button 10.1 is used to stop the system.
Chemical 1
Pump 1
(00.0)
Start
(10.0)
Stop
(10.1)
Process Control
Pump 2
(001)
Mixer
Motor
(00.2)
Drain Valve (Q0.3)
Pump 3
(20.4)
Chemical 2
Transcribed Image Text:Design a ladder program to run the material mixing system according to the following information: 1- When the start push button 10.0 is pressed, the pump (PUMP1 Q0.0) works for five seconds and then stops. 2- After that, the pump (PUMP2 Q0.1) runs for three seconds and then stops. 3- After that the pump (Mixer Motor Q0.2) works for 60 sec and then stops. 4- After that, the control valve (drian valve Q0.3) is opened, the pump (PUMP3 Q0.4) works for ten seconds. 5- The stop push button 10.1 is used to stop the system. Chemical 1 Pump 1 (00.0) Start (10.0) Stop (10.1) Process Control Pump 2 (001) Mixer Motor (00.2) Drain Valve (Q0.3) Pump 3 (20.4) Chemical 2
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Analysis of Multiple Order System and Steady State Error
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,