Consider the following data set: Sample Corrected Absorbance at 470 nm 100 ug/ml CuSO. standard 200 ug/mL CuSO. standard 300 ug/ml Cuso. standard 0.032 0.058 0.090 400 ug/ml CuSO. standard 500 ug/ml Cuso. standard CusO. Solution with Unknown Concentration 0.114 0.140 0.070 1. Plot (Using MS Excel) or draw by hand a standard calibration curve for samples 1 to 5. Determine the molar absorptivity using the absorbance of the 100 ug/mL CuSo, standard. (Note: Convert ug/ml to Molarity first using the molar mass of the standard which is 249.685 g/mol). l 2. Write the resulting linear regression equation and R of the plotted standard calibration curve. 3. Calculate the concentration of the "CuSO. Solution with Unknown Concentration" using the produced linear regression equation from the standard calibration curve and its absorbance at 470 nm.

Appl Of Ms Excel In Analytical Chemistry
2nd Edition
ISBN:9781285686691
Author:Crouch
Publisher:Crouch
Chapter4: Least-squares And Calibration Methods
Section: Chapter Questions
Problem 9P
icon
Related questions
Question
100%
Consider the following data set:
Sample
Corrected Absorbance at 470 nm
100 ug/ml CuSO. standard
0.032
200 µg/ml Cuso. standard
0.058
300 ug/ml CusO. standard
400 µg/ml CuSO. standard
0.090
0.114
500 ug/ml CusO standard
0.140
CusO. Solution with Unknown Concentration
0.070
1. Plot (Using MS Excel) or draw by hand a standard calibration curve for samples 1 to 5. Determine the
molar absorptivity using the absorbance of the 100 ug/ml Cuso, standard. (Note: Convert ug/ml to
Molarity first using the molar mass of the standard which is 249.685 g/mol).
2. Write the resulting linear regression equation and R of the plotted standard calibration curve.
3. Calculate the concentration of the "CuSO. Solution with Unknown Concentration" using the produced
linear regression equation from the standard calibration curve and its absorbance at 470 nm.
Transcribed Image Text:Consider the following data set: Sample Corrected Absorbance at 470 nm 100 ug/ml CuSO. standard 0.032 200 µg/ml Cuso. standard 0.058 300 ug/ml CusO. standard 400 µg/ml CuSO. standard 0.090 0.114 500 ug/ml CusO standard 0.140 CusO. Solution with Unknown Concentration 0.070 1. Plot (Using MS Excel) or draw by hand a standard calibration curve for samples 1 to 5. Determine the molar absorptivity using the absorbance of the 100 ug/ml Cuso, standard. (Note: Convert ug/ml to Molarity first using the molar mass of the standard which is 249.685 g/mol). 2. Write the resulting linear regression equation and R of the plotted standard calibration curve. 3. Calculate the concentration of the "CuSO. Solution with Unknown Concentration" using the produced linear regression equation from the standard calibration curve and its absorbance at 470 nm.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 5 images

Blurred answer
Knowledge Booster
Spectroanalytical Methods
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning