A two-stage cascade refrigeration system operates between the condenser pressure of 440 psia and evaporator pressure of 120 psia with R-410a as the working fluid. Heat rejection from the lower cycle to the upper cycle takes place in an adiabatic counter-flow heat exchanger where the pressure in the upper and lower cycles are 220 psia and 230 psia, respectively. In both cycles, the refrigerant is a saturated liquid at the condenser exit and a saturated vapor at the compressor inlet, and the isentropic efficiency of the compressor is 80%. If the mass flow rate of the refrigerant through the lower cycle is 0.3 lb/s, determine: a. the mass flow rate of the refrigerant through the upper cycle Ib/s b. the rate of heat removal from the refrigerated space TR c. the rate of heat removal from the refrigeration system BTU/hr d. the actual total compressor power input, Hp e. the actual COP of this system

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter22: Condensers
Section: Chapter Questions
Problem 7RQ: When a standard-efficiency air-cooled condenser is used, the condensing refrigerant will normally be...
icon
Related questions
Question
Fill in the blanks:
A two-stage cascade refrigeration system operates between the condenser pressure of 440 psia and evaporator pressure of 120 psia
with R-410a as the working fluid. Heat rejection from the lower cycle to the upper cycle takes place in an adiabatic counter-flow heat
exchanger where the pressure in the upper and lower cycles are 220 psia and 230 psia, respectively In both cycles, the refrigerant is a
saturated liquid at the condenser exit and a saturated vapor at the compressor inlet, and the isentropic efficiency of the compressor
is 80%. If the mass flow rate of the refrigerant through the lower cycle is 0.3 lb/s, determine:
a. the mass flow rate of the refrigerant through the upper cycle
Ib/s
b. the rate of heat removal from the refrigerated space
TR
c. the rate of heat removal from the refrigeration system
BTU/hr
d. the actual total compressor power input,
Hp
e. the actual COP of this system
Transcribed Image Text:Fill in the blanks: A two-stage cascade refrigeration system operates between the condenser pressure of 440 psia and evaporator pressure of 120 psia with R-410a as the working fluid. Heat rejection from the lower cycle to the upper cycle takes place in an adiabatic counter-flow heat exchanger where the pressure in the upper and lower cycles are 220 psia and 230 psia, respectively In both cycles, the refrigerant is a saturated liquid at the condenser exit and a saturated vapor at the compressor inlet, and the isentropic efficiency of the compressor is 80%. If the mass flow rate of the refrigerant through the lower cycle is 0.3 lb/s, determine: a. the mass flow rate of the refrigerant through the upper cycle Ib/s b. the rate of heat removal from the refrigerated space TR c. the rate of heat removal from the refrigeration system BTU/hr d. the actual total compressor power input, Hp e. the actual COP of this system
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning