A real heat pump has .02 kg/s of refrigerant-134a flowing through and consumes 3 kW of power. The refrigerant is a mixture at 50% quality and 120 kPa entering the evaporator and leaves at 100 kPa and -20 C. The refrigerant enters the condenser at 1.4 MPa and leaves at 1.2 MPa. Assuming no loss in pressure or temperature in the connecting pipes, determine the temperature, pressure, enthalpy and entropy at all positions in the cycle, the heat transfer coming in and leaving, the COP of this heat pump, the isentropic efficiency of the compressor, and the rate of entropy generation in the compressor.
A real heat pump has .02 kg/s of refrigerant-134a flowing through and consumes 3 kW of power. The refrigerant is a mixture at 50% quality and 120 kPa entering the evaporator and leaves at 100 kPa and -20 C. The refrigerant enters the condenser at 1.4 MPa and leaves at 1.2 MPa. Assuming no loss in pressure or temperature in the connecting pipes, determine the temperature, pressure, enthalpy and entropy at all positions in the cycle, the heat transfer coming in and leaving, the COP of this heat pump, the isentropic efficiency of the compressor, and the rate of entropy generation in the compressor.
Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter28: Special Refrigeration Applications
Section: Chapter Questions
Problem 15RQ: Why is two-stage compression popular for extra-low-temperature refrigeration systems?
Related questions
Question
100%
A real heat pump has .02 kg/s of refrigerant-134a flowing through and consumes 3 kW of power. The refrigerant is a mixture at 50% quality and 120 kPa entering the evaporator and leaves at 100 kPa and -20 C. The refrigerant enters the condenser at 1.4 MPa and leaves at 1.2 MPa. Assuming no loss in pressure or temperature in the connecting pipes, determine the temperature, pressure, enthalpy and entropy at all positions in the cycle, the heat transfer coming in and leaving, the COP of this heat pump, the isentropic efficiency of the compressor, and the rate of entropy generation in the compressor.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 4 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning