10. A winter air conditioning system maintains a building at 21oC and 40% RH. The outdoor conditions are 0oC (DBT) and 100% RH. The sensible load load on the building is 100 kW, while the latent heating load is 25 kW. In the air conditioning system, 50% of the outdoor air (by mass) is mixed with 50% of the room air. The mixed air is heated in a pre-heater to 250C and then required amount of dry saturated steam at 1 atm. pressure is added to the pre-heated air in a humidifier. The humidified air is then heated to supply temperature of 450C and is then supplied to the room. Find a) The required mass flow rate of supply air, b) Required amount of steam to be added, and c) Required heat input in pre-heater and re-heater. Barometric pressure = 1atm..

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter45: Domestic Refrigerators And Freezers
Section: Chapter Questions
Problem 2RQ: The operating condition for the single compressor in a household refrigerator is the lowest box...
icon
Related questions
Question
10. A winter air conditioning system maintains a building at 210C and 40% RH.
The outdoor conditions are 0oC (DBT) and 100% RH. The sensible load load on
the building is 100 kW, while the latent heating load is 25 kW. In the air
conditioning system, 50% of the outdoor air (by mass) is mixed with 50% of the
room air. The mixed air is heated in a pre-heater to 250C and then required
amount of dry saturated steam at 1 atm. pressure is added to the pre-heated air
in a humidifier. The humidified air is then heated to supply temperature of 450C
and is then supplied to the room. Find a) The required mass flow rate of supply
air, b) Required amount of steam to be added, and c) Required heat input in
pre-heater and re-heater. Barometric pressure = 1atm..
Transcribed Image Text:10. A winter air conditioning system maintains a building at 210C and 40% RH. The outdoor conditions are 0oC (DBT) and 100% RH. The sensible load load on the building is 100 kW, while the latent heating load is 25 kW. In the air conditioning system, 50% of the outdoor air (by mass) is mixed with 50% of the room air. The mixed air is heated in a pre-heater to 250C and then required amount of dry saturated steam at 1 atm. pressure is added to the pre-heated air in a humidifier. The humidified air is then heated to supply temperature of 450C and is then supplied to the room. Find a) The required mass flow rate of supply air, b) Required amount of steam to be added, and c) Required heat input in pre-heater and re-heater. Barometric pressure = 1atm..
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning