10-mL aliquots of an environmental water sample were pipetted into five 50.00-mL volumetric flasks. Exactly 0.00, 5.00, 10.00, 15.00, and 20.00-mL of a standard solution containing 11.1 ppm Fe3+ were added to each, followed by an excess of thiocyanate ion to give the red complex Fe(SCN)2+. After dilution to volume, the instrumental response for each of the five solutions measured with a colorimeter was found to be 0.240, 0.437, 0.621, 0.809, 1.809, respectively. Using Excel and the LINEST function, what was the concentration in the water sample (including error)? [HINT: consider the type of calibration scheme used.]
10-mL aliquots of an environmental water sample were pipetted into five 50.00-mL volumetric flasks. Exactly 0.00, 5.00, 10.00, 15.00, and 20.00-mL of a standard solution containing 11.1 ppm Fe3+ were added to each, followed by an excess of thiocyanate ion to give the red complex Fe(SCN)2+. After dilution to volume, the instrumental response for each of the five solutions measured with a colorimeter was found to be 0.240, 0.437, 0.621, 0.809, 1.809, respectively. Using Excel and the LINEST function, what was the concentration in the water sample (including error)? [HINT: consider the type of calibration scheme used.]
Chemistry: Principles and Reactions
8th Edition
ISBN:9781305079373
Author:William L. Masterton, Cecile N. Hurley
Publisher:William L. Masterton, Cecile N. Hurley
Chapter15: Complex Ion And Precipitation Equilibria
Section: Chapter Questions
Problem 68QAP
Related questions
Question
10-mL aliquots of an environmental water sample were pipetted into five 50.00-mL volumetric flasks. Exactly 0.00, 5.00, 10.00, 15.00, and 20.00-mL of a standard solution containing 11.1 ppm Fe3+ were added to each, followed by an excess of thiocyanate ion to give the red complex Fe(SCN)2+. After dilution to volume, the instrumental response for each of the five solutions measured with a colorimeter was found to be 0.240, 0.437, 0.621, 0.809, 1.809, respectively.
Using Excel and the LINEST function, what was the concentration in the water sample (including error)? [HINT: consider the type of calibration scheme used.]
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 4 steps with 1 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Recommended textbooks for you
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781337399074
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781337399074
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning